Bipedicular kyphoplasty for an L5 compression fracture

  • Vertebral compression fracture
  • Kyphoplasty

Cement from the first pedicle filled only part of the L5 fracture cleft.

The L5 fracture on CT

Sagittal view of the L5 fracture.
The coronal view shows the depressed upper endplate.

Access through the first pedicle

The first cannula enters L5 through one pedicle.

A second pedicle for the unfilled cleft

Kyphoplasty through one pedicle usually works. When the fill is inadequate, a second approach through the opposite pedicle is needed, because the fill is critical to symptom relief.

Cement from the first side fills only part of the cleft. The second cannula approaches the unfilled portion from the opposite side.

Final cement fill

After the second injection, cement extends across the fracture.
Lateral view of the final cement fill.