A venous ulcer from one incompetent perforator
A 69-year-old man had an open ulcer on his left leg. He had already had an ultrasound and had been told that venous disease was not the cause of his ulcer.
Above the inner ankle
The ulcer was on the inside of the leg, just above the ankle, in a patch of dark, discolored skin.
One incompetent perforator
Duplex ultrasound found an incompetent perforator in the distal calf, just above the ulcer. It measured 3.65 mm across and refluxed for 2.59 seconds. A varicose vein at the ulcer also refluxed. There was no other superficial venous incompetence.
This case illustrates the importance of a technologist with dedicated venous training, who understands venous disease and is well supervised by a physician who understands it: not all venous ultrasound studies are the same.
Closing the perforator with VenaSeal
The perforator was closed with VenaSeal, a cyanoacrylate adhesive. Under ultrasound guidance, about 0.3 mL was delivered through a micropuncture needle with a tuberculin syringe, which gives better hand control over the delivery. The varicose vein at the ulcer was treated with foam sclerotherapy.
VenaSeal is approved for closing superficial truncal veins such as the great saphenous vein, so its use in a perforator is off-label. A feasibility study of the VenaSeal adhesive in perforators reported that 76% closed.1 In a later series of cyanoacrylate injected directly into incompetent perforators under ultrasound, 96.3% were closed at about two weeks and 86.5% at about ten weeks.2 Among 187 patients with open venous ulcers treated with a different cyanoacrylate adhesive, the perforators were closed and the ulcer had healed completely in 87.1% at 12 months.3
The ulcer healed
Less than four months after the duplex, the ulcer had healed.
References
- Toonder IM, Lam YL, Lawson J, Wittens CH. Cyanoacrylate adhesive perforator embolization (CAPE) of incompetent perforating veins of the leg, a feasibility study. Phlebology. 2014;29(1 suppl):49–54. https://doi.org/10.1177/0268355514529696
- Mordhorst A, Yang GK, Chen JC, Lee S, Gagnon J. Ultrasound-guided cyanoacrylate injection for the treatment of incompetent perforator veins. Phlebology. 2021;36(9):752–760. https://doi.org/10.1177/02683555211015564
- Türkmen U. Single-center clinical experience of cyanoacrylate embolization method for incompetent perforating veins in treating CEAP-6 patients. J Vasc Surg Venous Lymphat Disord. 2024;12(6):101939. https://doi.org/10.1016/j.jvsv.2024.101939